Rogowski Coils

1. Open-ended and flexible, allowing it to be wrapped around a live conductor without disturbing it
2. High-current Rogowski coils to be calibrated using much smaller reference current
3. No danger of opening the secondary winding
4. Lower construction costs
5. Temperature compensation is simple
6. Smaller than an equivalent rating current transformer.

Additional information

Rated Primary Current

1000~5000A

Rated Frequency

45Hz-600Hz

Output Voltage Vo

0.333mv

Accuracy

1.0~3.0

Dielectric Withstanding

3000Vrms/2 seconds  between sec. / outside

Product Details:

Application Scenarios For

Flexible Rogowski Coils​

If you need a coil to have the characteristics of real-time current measurement function, fast response speed, and not saturated, apply AC power, especially the measurement of high -frequency large current.

Then Rogowski is a wise choice.

Xiamen ZTC Technology Rogowski coils have been successfully applied to many fields, such as power measurement, equipment monitoring, and detection of leakage current.

Electrical safety: Fault testing for UPS ( uninterruptible power supplies )

The current output of a high-power uninterruptible power supply for emergency backup was measured and monitored during conversion to emergency backup to determine whether there were any discontinuities in the current waveform that could adversely affect the power station equipment.

Energy management: Power management metering

Thanks to its flexible construction, the Rogowski can be easily installed around the conductor under test even if there is only limited space around it.

Rogowski coil Application

Power equipment application: tracing earth faults in transmission and distribution systems

When an earth fault is detected in the main output connection of a large generator, the generator is put out of service. When a Rogowski coil is installed, this fault can easily be traced and thus resolved.

Monitoring applications: testing current transformer secondary currents

In some systems related to metering currents, it is most important that the secondary circuit is not disturbed. Rogowski coils can be used to monitor the secondary current without any disconnection being required. The use of Rogowski coils ensures that no additional impedance is reflected into the secondary circuit.

rogowski coil

Electrical Specification (Customized Available)

Power Supply:  12VDC,50mA  MAX

Oprating frequncy : 45Hz-600Hz

Rated primary current : 1000A

Rated output voltage:  0.333mv

Current range:  10A-6000A

Accuracy class:  1.0~3.0

Dielectric voltage(Hi-pot):  3000Vrms/2 seconds  between sec. / outside

Ambient storage temperature:   -40~+70ºC

Ambient operating temperature:  -35~+70ºC

rogowski Coil Sensor

Dimensions And Installation Guides

rogo CT

Rogowski Coils size and cable length can be tailor made, integrator is available if needed.

1 Before the installation must ensure that the primary is no current status.
2 Correct mouting of the CT is assured by a distinct sound of a “click”.
3 When Install CTs into circuit box, the circuit box’s main breaker should be turned off.

Rogo CT guideline

How can we help you?

As a high-tech orientation enterprise and industrial manufacturing entity, we dedicate provide our valued customers from design concept to final products delivery.

Industry Expertise And Professional Advice

We have well educated engineers collaborate with rich experienced technican dedicating to project developing and problem solving. Providing professional advice for split core current sensor, differential current transformer mechanical design, electrical parmeters setting for EV charging solution, energy monitor system application.

workshop

High Efficiency And Sufficient Production Capacity

Our plant covers 20,000 square meters holding more than 300 well skilled workers and hundreds winding machines and testing instruments with automated equipments. We are pleasure to meet your requirments at different stages of project, small lot and bulk orders are all available for manufacturing.

zero phase current sensor

Stable Performance And Reliable Quality

As current transformers are kinds of critical components used for electrical safety devices, we highly value quality in the whole process. By doing 100% incoming and outcoming inspection, customers are satisfied with our strict quality control.

QUALITY CONTROL

Incoming Inspection

In-process Inspection

Outgoing Inspection

Samples & Orders Lead Time​

standard samples

Tailor Made Lead Time

If some special materials are needed, the lead time also depends on suppliers’ lead time. If toolings are required, the samples can only be made after tooling finished.

production

Shipping TIme

Deponds on shipping distance, courier delivery around 2~5 days, Air shipping 3~7 days, Sea shipping 7~40 days. We can choose a best way by considering products’weight,urgency of need and commodities value.

Regular Item Lead Time

For the regular items, if there is stock, we can ship few pieces for your testing in 1~2 days. If not, we need to prepare samples in 3~4 days.

customized

Production Lead Time

The lead time depends on the material and production time frame and the order quantity. Generally, the materials lead time 1~2 weeks, production time 2~3 weeks.

shipping

Our Amazing Clients:

What People Say?​

"As a procument manager in energy management company, we value a supplier provide a steay supply chain and good quality current transformer. Honestly, cooperate with Xiamen ZTC Technology is wise choise."
manager
Tom Sendler
Technician
"When I have someting need to be assisted in projects,I can get fast technical respond from Xiamen ZTC Technology everytime.Good after-sales service from their team."
procument manager
Grant Gabriel
Procument manager
"ZTC series of AC Split core current transformers are a simple to use, compact split-core design which is easily installed for metering applications. I love it."
electrician
Dave Jan
Electrican
"ZTC series of current transformers for RCD EV charing module are compact design, steady quality performance which ensure high pass rate for volume produciton."
operator
Sam Tong
PCB assembly operator
Play Video

Our Story

Xiamen ZTC Technology Co., Ltd (Zentar® ) found in 1993 is located in Xiamen, a harbor city in Southeast China. It is about 3 hours by high-speed train far from Shenzhen.

We are a leading manufacturer of current transformers for electrical safety and electric measuring industry. By three decades development, around 250 workers producing more than 2000+ customized products to meet customers’ various needs. 

As an innovation-oriented enterprise and IATF16949 factory, we bring into automated equipments and machines to increase production efficiency and meet customers in auto industry high quality standard.

Stay ahead, and constantly committed to advanced technologies, research and development of new products and new markets. Providing high quality current transformers and expertise in assisting customers develop and launch projects for EV charging modules, GFCI, RCD and wireless energy monitors.

Talk To ZTC Now!​

To Discuss Your Need Of Current Transformers For Electric Metering Or Electrical Safety. Tailor Made Products And Customized Solutions Are Welcome.


    TE-Crew